ARJAY ENGINEERING EC-Gold Dual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sistemas de segurança - controlo de acesso ARJAY ENGINEERING EC-Gold Dual. ARJAY ENGINEERING EC-Gold Dual User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 22
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
PG-2000
CENTRAL ACCESS PANEL (CAP)
For EC-GOLD TRANSMITTERS
User Manual
Technical Support
Continental North America Toll Free 1-(800) 387-9487
Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701
A Product of Arjay Engineering Ltd.
Oakville, Ontario, Canada
www.ArjayEng.com
www.EnmetGasDetection.com
Vista de página 0
1 2 3 4 5 6 ... 21 22

Resumo do Conteúdo

Página 1 - For EC-GOLD TRANSMITTERS

PG-2000 CENTRAL ACCESS PANEL (CAP) For EC-GOLD TRANSMITTERS User Manual Technical Support Continental North America To

Página 2 - Flexible monitoring and

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 8 - The bottom line displays the common alarm status. Based on the current alarm state, “OK”, “Low

Página 3 - Features and Benefits

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 9 - Each zone may have 2 mA modules: one for the max ppm in the zone and the other for the average p

Página 4 - TABLE OF CONTENTS

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 10 - 3.6 SET ALARM VALUES, DELAYS AND RELAY MAP 1. Press the CONT key then press 1 for Gas Alarms

Página 5 - 1.0 INSTRUMENT OVERVIEW

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 11 - 4. After selecting the desired gas by pressing 1 in step above, enter the high and low thresho

Página 6 - Figure 1.0

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 12 - 4.0 MISCELANEOUS SETUP Each remote EC Gold transmitter may be individually setup and calibrated

Página 7 - 1.3 SPECIFICATIONS

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 13 - 3. At the prompt, enter the address number of the desired EC Gold transmitter to be calibrated

Página 8 - 2.0 INSTALLATION

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 14 - 5.0 BMCS ACCESS The Enmet CAP's (Central Access Panels or Scanners) may be accessed via an

Página 9 - 3.3 DISPLAY SCREENS

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 15 - 6.0 SETTINGS SHEET Checked by Model Number Serial Number Hardware Rev. Software Rev. The f

Página 10 - - 8

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 16 - Code 23 = Unused Low Alarm high threshold Low Alarm low threshold High Alarm high thres

Página 11 - - 9

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 17 - Relay Mapping (Circles specifys the factory setting of "YES" as per job specification

Página 12 - - 10

Toxic Gas Monitor For Ventilation ControlThe PG-2000 offers an intelligent solution togas monitoring and ventilation control. Morethan 30 years of gas

Página 16 - 5.0 BMCS ACCESS

Arjay Engineering Ltd. 2851 Brighton RoadOakville, OntarioCanadaL6H 6C9tel ++1 905-829-2418fax++1 905-829-4701N. America 1-800-387-9487email arjay@a

Página 17 - Number of Sensors

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 2 - TABLE OF CONTENTS 1.0 INSTRUMENT OVERVIEW ...

Página 18 - - 16

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 3 - 1.0 INSTRUMENT OVERVIEW 1.1 FEATURES • Automatic scanning of up to 80 EC Gold network sensors.

Página 19

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 4 - For each zone, the maximum and average ppm values are calculated and transmitted on optional 4-2

Página 20

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 5 - 1.3 SPECIFICATIONS OPERATION The CAP can access a maximum of 80 EC Gold transmitters assigne

Página 21

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 6 - 2.0 INSTALLATION See drawings at back of manual. 3.0 STARTUP AND CONFIGURATION Figure 3.0 3.1

Página 22

Model: PG-2000 pg2000capum45.DOC Rev: 4.5 - 7 - 3.3 DISPLAY SCREENS After powerup, and the initial startup screen has been displayed for about 3

Comentários a estes Manuais

Sem comentários